AlphalinerHP | High Performance
Sewer rehabilitation in sensitive areas with high demands on safety
Areas of use: Municipalities / industry
Trenchless rehabilitation of sewers using RELINEEUROPE's seamless GRP hose liners and innovative UV light curing has proven itself in practice to be a safe and efficient process.
Advantages that are especially useful for the rehabilitation of sewers in areas with particularly demanding safety requirements, such as in ground water protection zones:
- Leak test requirements of varying severity
- Ground water protection zones II and III
- High-intensity traffic zones
- Development areas / areas of mining subsidence / marshland
Especially demanding requirements are placed on sewer rehabilitation systems in these areas: no ground water contamination during the rehabilitation project; greater and longer impermeability conditions, etc.
RELINEEUROPE's AlphalinerHP is a hose liner system meeting these demanding requirements. High standards – additional safety barrier for twice the safety!
Smooth, resin-rich inner surface / wearing course
Due to the especially resin-rich inner layer, the smooth inner surface of the Alphaliner has the best hydraulic properties. This wearing course is 0.5mm thick, giving the Alphaliner the greatest abrasion resistance in terms of mechanical stress loads. An added advantage: deposits and incrustations have little chance.
Glass fibre reinforcement / composite thickness
The special glass fibre reinforcement and the resulting high mechanical characteristic values give the liner pipe a high degree of structural and dynamic durability.
Resin-rich double wall
The AlphalinerHP has a special and unique sandwich construction. The resin-rich internal layer and the structurally supporting part of the glass fibre reinforcement is completed with an especially resin-rich rear wall. Whereas conventional hose liners use outer films only on their backings, this special resin-rich rear wall provides extra safety in particularly demanding applications in regard to infiltration and exfiltration.
We offer you the following models:
- Alphaliner500-HP
- Alphaliner1500-HP
- Alphaliner1800-HP
Optionally, we offer these Alphaliners with integrated slide protection and/or pre-liner.
Characteristics | Alphaliner500G | Alphaliner1800 | Alphaliner1800H |
---|---|---|---|
E-Module acc. to DIN EN 1228 | 13,265 MPa | 24,507 MPa | 26,581 MPa |
E-Module Short-term exposure value acc. to DIN EN 1228 | 9,776 MPa | 19,541 MPa | 21,209 MPa |
E-Module Long-term exposure value acc. to DIN EN 1228 | 6,110 MPa | 14,804 MPa | 16,190 MPa |
E-Module Short-term exposure value acc. to DIN EN ISO 178 | 8,500 MPa | 18,406 MPa | 19,062 MPa |
Flexural strength Short-term exposure value acc. to DIN EN ISO 178 | 180 MPa | 300 MPa | 380 MPa |
Flexural strength Long-term exposure value | 110 MPa | 227 MPa | 290 MPa |
Reduction factor 50 years | 1.6 | 1.32 | 1.31 |
Glass fibre quality | ECR | ECR | ECR |
UP resin acc. to DIN EN 13121 | Group 4 | Group 4 | Group 4 |
UP resin acc. to DIN 16946-2 | Type 1140 | Type 1140 | Type 1140 |
UP resin acc. to DIN 18820 | Group 3 | Group 3 | Group 3 |
Abrasion resistance acc. to CEN/TR 15729 | 0.09 mm | 0.12 mm | 0.12 mm |
Wearing course glas-bonded (AL500G) vylene-bonded (AL1800) | 0.3 mm | 0.5 mm | 0.5 mm |
Individual length | ≤ 300 | ≤ 300 | ≤ 300 |
Wall thicknesses | ≤ 25.2 mm | ≤ 25.2 mm | ≤ 25.2 mm |
Diameter Circular cross-sections | DN150-DN1800 | DN150-DN1800 | DN150-DN1800 |
Diameter Ovoid cross-sections | 200/300 – 1200/1800 | 200/300 – 1200/1800 | 200/300 – 1200/1800 |
DWA-M 114-3 classification | 13 | 23 | 25 |
Philipp Martin
Managing Director Sales Europe RELINEEUROPE AG
Phone: +49 6349 93934-220
E-mail: philipp.martin@relineeurope.com